![]() | Error situations |
Mode | LCD | Display error | To solve the problem |
---|---|---|---|
P A M | no ISO value or frame number is displayed | press select button | |
P A M | [0] | flashing | load film again or remove rewinded film |
P A M | b.c. | flashing / continuously displayed | replace battery (Li2cr5) / immediately |
P A M | . . . | continuously displayed | switch to M mode and back |
P A M | EEE * | continuously displayed | camera lens blocked, remove battery and / or obstruction For instance a mounted UV filter and short focus distance |
P A M | dark | continuously displayed | temperature to high, keep camera in shade |
P A M | slow reaction | temperature to low, keep camera warm ( -10°C +40°C ) | |
A | 1/250 | flashing | over exposure, set aperture to larger value |
A | 30 | flashing | under exposure, set aperture to smaller value |
M | 2 | flashing | under exposure, set exposure time to larger value |
M | 22 | flashing | over exposure, set exposure time to smaller value |
M | shutter speed | flashing | exposure exceeds Exposure Display Range (EV 3-18) This has no effects on camera functioning |
Silent mode | flashing,film rewinding stops | low battery voltage
press rewind button or switch camera off and on |
*See Filters and short focusing distance. |